About the S200
Scientific Air’s S200 goes way beyond air filtration alone.
After first phase HEPA particulate filtration, pathogens smaller than 0.3 microns pass into the S200 patented UV-C Air Suspension Chamber.
Inside the chamber germs are held close enough and long enough for a laboratory tested kill rate of up to 99.9994% of airborne norovirus surrogate.
Norovirus is one of the most difficult viruses to kill, and shares numerous properties with the small non-enveloped RNA strain SARS-CoV-2.
Thorough air disinfection of a standard 800 cubic ft. room in minutes. Whole-room air exchange within minutes. No ozone production, no external UV-C exposure, and kills VOCs and odors.
The S200 size and materials make it easy to move, easy to set up, and long-lasting. All-steel, antimicrobial coatings are combined with a low tip-proof center of gravity on a high-quality hospital grade locking wheeled base. The S200 is low maintenance, uses about as much power as an average residential ceiling fan, and operates quietly.


The S200 delivers the highest air disinfection levels in cubic feet per minute for its size. With 3x the standard concentration of UV-C light for disinfection, HEPA filtration, and specially formulated carbon, the S200 removes pathogens, particulates, odors, and VOCs — quickly.
High rate of cubic feet per minute of air scrubbed, the S200 cleans air faster for its size than any other air disinfection system — 24/7 in occupied rooms . Performing HEPA filtration, UV-C pathogen elimination, and carbon cleansing simultaneously, making the medical environment safer, faster.
The most prevalent way germs travel is often over looked — through the air.
Particulate Management
24/7 viable and non-viable particulate UV-C disinfection, safe for patients and staff in occupied areas.
Hospital field studies report 70% reductions in non-viable airborne particulates with the S200 HEPA filtration medium, powerful results regardless of the shortcomings and/or inconsistencies in existing HVAC systems.





Benefits
The S200’s 270-degree airflow system produces non-distributive (i.e. uniform), low-pressure, viscous air movement. This creates continuous, large-scale air-scrubbing, air-flow vortices throughout the room.
Tested nationally recognized full room size laboratories with a kill rate of up to 99.9994% of airborne norovirus surrogate, one of the most difficult viruses to kill, and replicating small non-enveloped RNA strain SARS-CoV-2.
The S200 airflow goes virtually unnoticed by both patients and staff. Air disinfection runs uninterrupted 24/7, even while the room is occupied.
Why Choose S200
1/3 of the price compared to leading competition



Standard 110-120 outlet using as little energy as a ceiling fan
Full Manufacturer’s Warranty with easy DIY maintenance programs available
Total Cubic Feet :
Scientific Air 400 | Minutes Needed | Hours Needed |
---|---|---|
99% Reduction | ||
99.99% Reduction | ||
99.9995% Reduction | ||
Air Changes Per Hour |